XNX 固定式通用型气体探测器
XNX通用型变送器标志着霍尼韦尔探测器在气体探测方面新的转变。它作为公共平台支持种类繁多的传感器或探测器,并标配HART载波4-20mA输出,为输入输出提供更多的模块化选择。
XNX的设计保证了灵活的集成、简单的安装、用户友好型操作以及简易的维护。它是用于各种气体检测控制器或工业标准PLC的理想选择。如果使用霍尼韦尔探测器气体监控解决方案,无论在何种情况下,用户都可得到保护。
可探测气体类型
Combustiable Gas/O2/H2S/CO/SO2/NH3/CL2/CLO2/NO/NO2/H2/HCL/HF/PH3/CO2...
Product Overview
XNX's advantage comes from a simple-to-use, low-maintenance universal platform that works with other safety equipment on a digital bus system, including Honeywell Analytics’ own Searchline Excel, Optima or other gas detectors, industry standard PLCs and third-party gas monitoring controllers.
XNX supports Electrochemical, Infrared and Catalytic Bead gas monitors and uses standard 4-20mA wiring and HART; options include Modbus, Fieldbus (pending) up to three relays and a local Hart Adapter for configuration and diagnostics using existing HART handheld devices.
With 200+ unique configurations, XNX satisfies Class 1/Class 2 intrinsically safe, explosion-proof requirements in upstream/downstream oil, chemical, wastewater and other industries.
The enclosure is available in stainless steel or aluminum, with a marine-grade coating. Five threaded ports, available in metric or NPT versions, and ruggedized mounting options provide ultimate installation flexibility. Instrumentation built on various sensing technologies can be attached locally to the transmitter or remotely with the appropriate accessories.
XNX™ Universal Transmitter
Supports the widest range of sensors on a common platform and offers a modular choice of inputs and outputs (saving customers time and money).
Features & Benefits
Flammable gas detection 0 to 100% LFL/LEL
Flexible operation options
Minimal training required
Quick Specs
Material: LM25 aluminum, painted (SS316 painted optional)
Temperature: -40° to +65°C / -40° to +150°F (sensor dependent)
Humidity: 20 to 90% RH (non-condensing)
Ordering Information
The XNX part numbering system contains all necessary information to convey the product configuration including options. Agency, Port
Thread, Enclosure Material, Sensor Personality define the standard unit. Three option fields are used to define optional Relay or Fieldbus
interfaces and factory installed local HART®.
Technical Summary
XNX is an extremely flexible gas transmitter that can be configured to accept an input from any of the Honeywell Analytics range of gas sensor technologies.
It can also be configured to provide all the industry standard output signals; a key feature of the XNX transmitter is that it comes with HART over 4-20mA as standard. This enables users to have a single type of interface to all their gas detection needs, even when different types of detectors are employed.
XNX is ATEX, IECEx, UL, CSA and SIL2 approved and is housed in a flameproof enclosure available in either marine grade painted aluminium LM25 or stainless steel 316. A large backlit multilingual LCD clearly indicates the unit’s status using a combination of text, digits and icons. Users can configure or conduct routine maintenance via magnet switches without ever needing to open the unit. An optional local IS HART® terminal port is also available if local interrogation is required. Local LEDs are also provided to indicate the unit’s status at a glance.
1. XNX Universal Transmitter- Flammable Standard Temperature with MPD sensor
XNX Universal transmitter for the Multi - Purpose Detector (MPD) sensor for flammable gases.
1.1. INSTRUMENT
XNX Aluminium Transmitter ATEX/IEC/INMETRO with MPD Flammable Catalytic Sensor 0-100%LEL
XNX-AMAV-NNCB1 |
XNX Gas Detector, HART® over 4-20mA output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL |
XNX-AMAV-NHCB1 |
XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL |
XNX-AMAV-RNCB1 |
XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL |
XNX-AMAV-RHCB1 |
XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL |
XNX-AMAV-MNCB1 |
XNX Gas Detector, HART® over 4-20mA and Modbus output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL |
XNX-AMAV-MHCB1 |
XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL |
XNX-AMAV-NNCB2 |
XNX Gas Detector, HART® over 4-20mA output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-101%LEL |
XNX-AMAV-NHCB2 |
XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD catalytic sensor 0-101%LEL |
XNX Stainless Steel Transmitter ATEX/IEC with MPD Flammable Catalytic Sensor 0-100%LEL |
||
XNX-AMSV-NNCB1 |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, including MPD catalytic sensor 0-100%LEL. |
|
XNX-AMSV-NHCB1 |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with local HART® interface port, including MPD catalytic sensor 0-100%LEL. |
|
XNX-AMSV-RNCB1 |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs, including MPD catalytic sensor 0-100%LEL. |
|
XNX-AMSV-RHCB1 |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, including MPD catalytic sensor 0-100%LEL. |
|
XNX-AMSV-MNCB1 |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output, including MPD catalytic sensor 0-100%LEL. |
|
XNX-AMSV-MHCB1 |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, including MPD catalytic sensor 0-100%LEL. |
|
XNX-AMSV-FNCB1 |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, including MPD catalytic sensor 0-100%LEL. |
|
XNX-AMSV-FHCB1 |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, including MPD catalytic sensor 0-100%LEL. |
|
|
|
|
XNX Aluminium Transmitter ATEX/IEC/INMETRO with MPD IR Hydrocarbon (Propane) Sensor 0-100%LEL |
||
|
|
|
XNX-AMAV-NNIF1 |
XNX Gas Detector, HART® over 4-20mA output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL |
|
XNX-AMAV-NHIF1 |
XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL |
|
XNX-AMAV-RNIF1 |
XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL |
|
XNX-AMAV-RHIF1 |
XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL |
|
XNX-AMAV-MNIF1 |
XNX Gas Detector, HART® over 4-20mA and Modbus output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL |
|
XNX-AMAV-MHIF1 |
XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL |
|
XNX-AMAV-FNIF1 |
XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL |
|
XNX-AMAV-FHIF1 |
XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL |
|
|
|
|
XNX Stainless Steel Transmitter ATEX/IEC with MPD IR Hydrocarbon (Propane) Sensor 0-100%LEL |
||
|
|
|
XNX-AMSV-NNIF1 |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, including MPD IR flammable (propane) sensor 0-100%LEL. |
|
XNX-AMSV-NHIF1 |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with local HART® interface port, including MPD IR flammable sensor 0-100%LEL. |
|
XNX-AMSV-RNIF1 |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs, including MPD IR flammable sensor 0-100%LEL. |
|
XNX-AMSV-RHIF1 |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, including MPD IR flammable sensor 0-100%LEL. |
|
XNX-AMSV-MNIF1 |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output, including MPD IR flammable sensor 0-100%LEL. |
|
XNX-AMSV-MHIF1 |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, including MPD IR flammable sensor 0-100%LEL. |
|
XNX-AMSV-FNIF1 |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, including MPD IR flammable sensor 0-100%LEL. |
|
XNX-AMSV-FHIF1 |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, including MPD IR flammable sensor 0-100%LEL. |
|
|
|
|
XNX Aluminium Transmitter ATEX/IEC/INMETRO with MPD Infrared Methane Sensor 0-100%LEL (0-5%V/V). |
||
|
|
|
XNX-AMAV-NNIV1 |
XNX Gas Detector, HART® over 4-20mA output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) |
|
XNX-AMAV-NHIV1 |
XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) |
|
XNX-AMAV-RNIV1 |
XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) |
|
XNX-AMAV-RHIV1 |
XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) |
|
XNX-AMAV-MNIV1 |
XNX Gas Detector, HART® over 4-20mA and Modbus output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) |
|
XNX-AMAV-MHIV1 |
XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) |
|
XNX-AMAV-FNIV1 |
XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) |
|
XNX-AMAV-FHIV1 |
XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) |
|
|
|
|
XNX Stainless Steel Transmitter ATEX/IEC with MPD Infrared Methane Sensor 0-100%LEL (0-5%V/V). |
||
|
|
|
XNX-AMSV-NNIV1 |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, including MPD IR methane sensor 0-100%LEL (0-5%V/V). |
|
XNX-AMSV-NHIV1 |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional local HART® interface port, including MPD IR methane sensor 0-100%LEL (0-5%V/V). |
|
XNX-AMSV-RNIV1 |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional alarm and fault relay outputs, including MPD IR methane sensor 0-100%LEL (0-5%V/V). |
|
XNX-AMSV-RHIV1 |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional alarm and fault relay outputs and local HART® interface port, including MPD IR methane sensor 0-100%LEL (0-5%V/V). |
|
XNX-AMSV-MNIV1 |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Modbus® output, including MPD IR methane sensor 0-100%LEL (0-5%V/V). |
|
XNX-AMSV-MHIV1 |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Modbus® output and local HART® interface port, including MPD IR methane sensor 0-100%LEL (0-5%V/V). |
|
XNX-AMSV-FNIV1 |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, including MPD IR methane sensor 0-5%V/V. |
|
XNX-AMSV-FHIV1 |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, including MPD IR methane sensor 0-5%V/V. |
|
|
|
|
XNX Aluminium Transmitter ATEX/IEC/INMETRO with MPD Infrared CO2 Sensor 0-5%V/V. |
||
|
|
|
XNX-AMAV-NNIC1 |
XNX Gas Detector, HART® over 4-20mA output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v |
|
XNX-AMAV-NHIC1 |
XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v |
|
XNX-AMAV-RNIC1 |
XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v |
|
XNX-AMAV-RHIC1 |
XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v |
|
XNX-AMAV-MNIC1 |
XNX Gas Detector, HART® over 4-20mA and Modbus output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v |
|
XNX-AMAV-MHIC1 |
XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v |
|
XNX-AMAV-FNIC1 |
XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v |
|
XNX-AMAV-FHIC1 |
XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v |
|
|
|
|
XNX Stainless Steel Transmitter ATEX/IEC with MPD Infrared CO2 Sensor 0-5%V/V. |
||
|
|
|
XNX-AMSV-NNIC1 |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, including MPD IR CO2 sensor 0-5%V/V. |
|
XNX-AMSV-NHIC1 |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with local HART® interface port, including MPD IR CO2 sensor 0-5%V/V. |
|
XNX-AMSV-RNIC1 |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs, including MPD IR CO2 sensor 0-5%V/V. |
|
XNX-AMSV-RHIC1 |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, including MPD IR CO2 sensor 0-5%V/V. |
|
XNX-AMSV-MNIC1 |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output, including MPD IR CO2 sensor 0-5%V/V. |
|
XNX-AMSV-MHIC1 |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, including MPD IR CO2 sensor 0-5%V/V. |
|
XNX-AMSV-FNIC1 |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, including MPD IR CO2 sensor 0-5%V/V. |
|
XNX-AMSV-FHIC1 |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, including MPD IR CO2 sensor 0-5%V/V. |
|
|
|
|
XNX Aluminium Transmitter UL/CSA with MPD Catalytic Sensor 0-100%LEL |
||
|
|
|
XNX-UTAV-NNCB1 |
XNX Gas Detector, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL |
|
XNX-UTAV-NHCB1 |
XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL |
|
XNX-UTAV-RNCB1 |
XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL |
|
XNX-UTAV-RHCB1 |
XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL |
|
XNX-UTAV-MNCB1 |
XNX Gas Detector, HART® over 4-20mA and Modbus output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL |
|
XNX-UTAV-MHCB1 |
XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL |
|
XNX-UTAV-FNCB1 |
XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL |
|
XNX-UTAV-FHCB1 |
XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL |
|
|
|
|
XNX Stainless Steel Transmitter UL/CSA with MPD Catalytic Sensor 0-100%LEL |
||
|
|
|
XNX-UTSV-NNCB1 |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, including MPD catalytic sensor 0-100%LEL. |
|
XNX-UTSV-NHCB1 |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with local HART® interface port, including MPD catalytic sensor 0-100%LEL. |
|
XNX-UTSV-RNCB1 |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs, including MPD catalytic sensor 0-100%LEL. |
|
XNX-UTSV-RHCB1 |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, including MPD catalytic sensor 0-100%LEL. |
|
XNX-UTSV-MNCB1 |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output, including MPD catalytic sensor 0-100%LEL. |
|
XNX-UTSV-MHCB1 |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, including MPD catalytic sensor 0-100%LEL. |
|
XNX-UTSV-FNCB1 |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, including MPD catalytic sensor 0-100%LEL. |
|
XNX-UTSV-FHCB1 |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, including MPD catalytic sensor 0-100%LEL. |
|
|
|
|
XNX Aluminium Transmitter UL/CSA with MPD Infrared Hydrocarbon (Propane) Sensor 0-100%LEL |
||
|
|
|
XNX-UTAV-NNIF1 |
XNX Gas Detector, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL |
|
XNX-UTAV-NHIF1 |
XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL |
|
XNX-UTAV-RNIF1 |
XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL |
|
XNX-UTAV-RHIF1 |
XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL |
|
XNX-UTAV-MNIF1 |
XNX Gas Detector, HART® over 4-20mA and Modbus output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL |
|
XNX-UTAV-MHIF1 |
XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL |
|
XNX-UTAV-FNIF1 |
XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL |
|
XNX-UTAV-FHIF1 |
XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL |
|
XNX Stainless Steel Transmitter UL/CSA with MPD Infrared Hydrocarbon (Propane) Sensor 0-100%LEL |
XNX-UTSV-NNIF1 |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, including MPD IR flammable sensor 0-100%LEL. |
|
XNX-UTSV-NHIF1 |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with local HART® interface port, including MPD IR flammable sensor 0-100%LEL. |
|
XNX-UTSV-RNIF1 |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs, including MPD IR flammable sensor 0-100%LEL. |
|
XNX-UTSV-RHIF1 |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, including MPD IR flammable sensor 0-100%LEL. |
|
XNX-UTSV-MNIF1 |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output, including MPD IR flammable sensor 0-100%LEL. |
|
XNX-UTSV-MHIF1 |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, including MPD IR flammable sensor 0-100%LEL. |
|
XNX-UTSV-FNIF1 |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, including MPD IR flammable sensor 0-100%LEL. |
|
XNX -UTSV-FHIF1 |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, including MPD IR flammable sensor 0-100%LEL. |
|
|
|
|
XNX Aluminium Transmitter UL/CSA with MPD Infrared Methane Sensor 0-100%LEL (0-5%V/V). |
||
|
|
|
XNX-UTAV-NNIV1 |
XNX Gas Detector, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) |
|
XNX-UTAV-NHIV1 |
XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) |
|
XNX-UTAV-RNIV1 |
XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) |
|
XNX-UTAV-RHIV1 |
XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) |
|
XNX-UTAV-MNIV1 |
XNX Gas Detector, HART® over 4-20mA and Modbus output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) |
|
XNX-UTAV-MHIV1 |
XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) |
|
XNX-UTAV-FNIV1 |
XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) |
|
XNX-UTAV-FHIV1 |
XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Methane) sensor 0-100%LEL (0-5%v/v) |
|
|
|
|
XNX Stainless Steel Transmitter UL/CSA with MPD Infrared Methane Sensor 0-100%LEL (0-5%V/V). |
||
|
|
|
XNX-UTSV-NNIV1 |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, including MPD IR methane sensor 0-100%LEL (0-5%V/V). |
|
XNX-UTSV-NHIV1 |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional local HART® interface port, including MPD IR methane sensor 0-100%LEL (0-5%V/V). |
|
XNX-UTSV-RNIV1 |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional alarm and fault relay outputs, including MPD IR methane sensor 0-100%LEL (0-5%V/V). |
|
XNX-UTSV-RHIV1 |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional alarm and fault relay outputs and local HART® interface port, including MPD IR methane sensor 0-100%LEL (0-5%V/V). |
|
XNX-UTSV-MNIV1 |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Modbus® output, including MPD IR methane sensor 0-100%LEL (0-5%V/V). |
|
XNX-UTSV-MHIV1 |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Modbus® output and local HART® interface port, including MPD IR methane sensor 0-100%LEL (0-5%V/V). |
|
XNX-UTSV-FNIV1 |
XNX transmitter, HART® over 4-20mA output,UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, including MPD IR methane sensor 0-5%V/V. |
|
XNX-UTSV-FHIV1 |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, including MPD IR methane sensor 0-5%V/V. |
|
|
|
|
XNX Aluminium Transmitter UL/CSA with MPD Infrared CO2 Sensor 0-5%V/V. |
||
|
|
|
XNX-UTAV-NNIC1 |
XNX Gas Detector, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v |
|
XNX-UTAV-NHIC1 |
XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v |
|
XNX-UTAV-RNIC1 |
XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v |
|
XNX-UTAV-RHIC1 |
XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v |
|
XNX-UTAV-MNIC1 |
XNX Gas Detector, HART® over 4-20mA and Modbus output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v |
|
XNX-UTAV-MHIC1 |
XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v |
|
XNX-UTAV-FNIC1 |
XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v |
|
XNX-UTAV-FHIC1 |
XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR CO2 sensor 0-5%v/v |
|
XNX Stainless Steel Transmitter UL/CSA with MPD Infrared CO2 Sensor 0-5%V/V. |
XNX-UTSV-NNIC1 |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, including MPD IR CO2 sensor 0-5%V/V. |
XNX-UTSV-NHIC1 |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with local HART® interface port, including MPD IR CO2 sensor 0-5%V/V. |
XNX-UTSV-RNIC1 |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs, including MPD IR CO2 sensor 0-5%V/V. |
XNX-UTSV-RHIC1 |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, including MPD IR CO2 sensor 0-5%V/V. |
XNX-UTSV-MNIC1 |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output, including MPD IR CO2 sensor 0-5%V/V. |
XNX-UTSV-MHIC1 |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, including MPD IR CO2 sensor 0-5%V/V. |
XNX-UTSV-FNIC1 |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, including MPD IR CO2 sensor 0-5%V/V. |
XNX-UTSV-FHIC1 |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, including MPD IR CO2 sensor 0-5%V/V. |
1.2. SPARE MPD SENSORS |
|
MPD: Multi-Purpose Detector (mV) - ATEX |
MPD-AMCB1 |
XNX MPD ATEX/IEC SENSOR CAT 0-100%LEL |
MPD-AMIV1 |
XNX MPD ATEX/IEC SENSOR IR CH4 0-100%LEL |
MPD-AMIF1 |
XNX MPD ATEX/IEC SENSOR IR 0-100%LEL |
MPD-AMIC1 |
XNX MPD ATEX/IEC SENSOR IR CO2 0-5%VV |
|
MPD: Multi-Purpose Detector (mV) - UL/CSA |
MPD-UTCB1 |
XNX MPD UL/CSA SENSOR CAT 0-100%LEL |
MPD-UTIV1 |
XNX MPD UL/CSA SENSOR IR CH4 0-100%LEL |
MPD-UTIF1 |
XNX MPD UL/CSA SENSOR IR 0-100%LEL |
MPD-UTIC1 |
XNX MPD UL/CSA SENSOR IR CO2 0-5%VV |
1.3. SPARE MPD REPLACEABLE CARTRIDGES |
1226A0359 |
XNX MPD CAT CARTRIDGE 0-100%LEL |
1226-0300 |
XNX MPD IR CARTRIDGE 0-100%LEL |
1226-0301 |
XNX MPD IR CARTRIDGE CO2 0-5%VV |
1226-0299 |
XNX MPD IR CARTRIDGE CH4 0-100%LEL |
2. XNX Universal Transmitter- for use with Sensepoint HT or 705 HT Flammable Sensor |
XNX Universal Transmitter excluding Sensepoint High Temp or 705 HT Sensor or remote configurations of MPD. Order required sensor separately from other appropriate section of price list. |
||
|
|
|
2.1. INSTRUMENT |
|
XNX Aluminium Transmitter ATEX/IEC for use with Sensepoint High Temperature Sensor |
XNX-AMAV-NNNNN |
XNX Transmitter, HART® over 4-20mA output, ATEX/IECEx, 5 x M25 entries, painted Aluminium, configured for Sensepoint High Temperature Sensor |
|
XNX-AMAV-NHNNN |
XNX Transmitter, HART® over 4-20mA output and local HART® interface port, ATEX/IECEx, 4 x M25 entries, painted Aluminium, configured for Sensepoint High Temperature Sensor |
|
XNX-AMAV-RNNNN |
XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays, ATEX/IECEx, 5 x M25 entries, painted Aluminium, configured for Sensepoint High Temperature Sensor |
|
XNX-AMAV-RHNNN |
XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays and local HART® interface port, ATEX/IECEx, 4 x M25 entries, painted Aluminium, configured for Sensepoint High Temperature Sensor |
|
XNX-AMAV-MNNNN |
XNX Transmitter, HART® over 4-20mA and Modbus output, ATEX/IECEx, 5 x M25 entries, painted Aluminium, configured for Sensepoint High Temperature Sensor |
|
XNX-AMAV-MHNNN |
XNX Transmitter, HART® over 4-20mA and Modbus output and local HART® interface port, ATEX/IECEx, 4 x M25 entries, painted Aluminium, configured for Sensepoint High Temperature Sensor |
|
XNX-AMAV-FNNNN |
XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output, ATEX/IECEx, 5 x M25 entries, painted Aluminium, configured for Sensepoint High Temperature Sensor |
|
XNX-AMAV-FHNNN |
XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, ATEX/IECEx, 4 x M25 entries, painted Aluminium, configured for Sensepoint High Temperature Sensor |
|
|
|
|
XNX Stainless Steel Transmitter ATEX/IEC for use with Sensepoint High Temperature Sensor |
||
|
|
|
XNX-AMSV-NNNNN |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, configured for mV sensors. |
|
XNX-AMSV-NHNNN |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with local HART® interface port, configured for mV sensors. |
|
XNX-AMSV-RNNNN |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs, configured for mV sensors. |
|
XNX-AMSV-RHNNN |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, configured for mV sensors. |
|
XNX-AMSV-MNNNN |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output, configured for mV sensors. |
|
XNX-AMSV-MHNNN |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, configured for mV sensors. |
|
XNX-AMSV-FNNNN |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, configured for mV sensors. |
|
XNX-AMSV-FHNNN |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, configured for mV sensors. |
|
XNX Aluminium Transmitter UL/CSA for use with 705 High Temperature Sensor |
XNX-UTAV-NNNNN |
XNX Transmitter, HART® over 4-20mA output, UL/CSA, 5 x 3/4"NPT entries, painted Aluminium, configured for 705 High Temperature Sensor |
XNX-UTAV-NHNNN |
XNX Transmitter, HART® over 4-20mA output and local HART® interface port, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, configured for 705 High Temperature Sensor |
XNX-UTAV-RNNNN |
XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA, 5 x 3/4"NPT entries, painted Aluminium, configured for 705 High Temperature Sensor |
XNX-UTAV-RHNNN |
XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays and local HART® interface port, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, configured for 705 High Temperature Sensor |
XNX-UTAV-MNNNN |
XNX Transmitter, HART® over 4-20mA and Modbus output, UL/CSA, 5 x 3/4"NPT entries, painted Aluminium, configured for 705 High Temperature Sensor |
XNX-UTAV-MHNNN |
XNX Transmitter, HART® over 4-20mA and Modbus output and local HART® interface port, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, configured for 705 High Temperature Sensor |
XNX-UTAV-FNNNN |
XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA, 5 x 3/4"NPT entries, painted Aluminium, configured for 705 High Temperature Sensor |
XNX-UTAV-FHNNN |
XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, UL/CSA, 4 x 3/4"NPT entries, painted LM25, configured for 705 High Temperature Sensor |
XNX Stainless Steel Transmitter UL/CSA for use with model 705 High Temperature Sensor |
XNX-UTSV-NNNNN |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, configured for mV sensors. |
XNX-UTSV-NHNNN |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with local HART® interface port, configured for mV sensors. |
XNX-UTSV-RNNNN |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs, configured for mV sensors. |
XNX-UTSV-RHNNN |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, configured for mV sensors. |
XNX-UTSV-MNNNN |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output, configured for mV sensors. |
XNX-UTSV-MHNNN |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, configured for mV sensors. |
XNX-UTSV-FNNNN |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, configured for mV sensors. |
XNX-UTSV-FHNNN |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, configured for mV sensors. |
3. XNX Universal Transmitter- for use with XNX Toxic & Oxygen Sensors |
XNX Universal Transmitter excluding toxic or oxygen sensor. Order required sensor separately from the XNX toxic and oygen sensors section below.
3.1. INSTRUMENT |
|
XNX Aluminium Transmitter ATEX/IEC/INMETRO for use with XNX Toxic and Oxygen Sensors |
XNX-AMAE-NNNNN |
XNX Transmitter, HART® over 4-20mA output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, configured for XNX toxic and oxygen sensors |
XNX-AMAE-NHNNN |
XNX Transmitter, HART® over 4-20mA output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, configured for XNX toxic and oxygen sensors |
XNX-AMAE-RNNNN |
XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, configured for XNX toxic and oxygen sensors |
XNX-AMAE-RHNNN |
XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, configured for XNX toxic and oxygen sensors |
XNX-AMAE-MNNNN |
XNX Transmitter, HART® over 4-20mA and Modbus output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, configured for XNX toxic and oxygen sensors |
XNX-AMAE-MHNNN |
XNX Transmitter, HART® over 4-20mA and Modbus output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, configured for XNX toxic and oxygen sensors |
XNX-AMAE-FNNNN |
XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output, ATEX/IECEx/INMETRO, 4 x M25 entries, painted Aluminium, configured for XNX toxic and oxygen sensors |
XNX-AMAE-FHNNN |
XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, ATEX/IECEx/INMETRO, 3 x M25 entries, painted Aluminium, configured for XNX toxic and oxygen sensors |
XNX Stainless Steel Transmitter ATEX/IEC for use with XNX Toxic and Oxygen Sensors |
XNX-AMSE-NNNNN |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, configured for XNX toxic and oxygen sensors. |
XNX-AMSE-NHNNN |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with local HART® interface port, configured for XNX toxic and oxygen sensors. |
XNX-AMSE-RNNNN |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs, configured for XNX toxic and oxygen sensors. |
XNX-AMSE-RHNNN |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, configured for XNX toxic and oxygen sensors. |
XNX-AMSE-MNNNN |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output, configured for XNX toxic and oxygen sensors. |
XNX-AMSE-MHNNN |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, configured for XNX toxic and oxygen sensors. |
XNX-AMSE-FNNNN |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, configured for XNX toxic and oxygen sensors. |
XNX-AMSE-FHNNN |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, configured for XNX toxic and oxygen sensors. |
XNX Aluminium Transmitter UL/CSA for use with XNX Toxic and Oxygen Sensors |
XNX-UTAE-NNNNN |
XNX Transmitter, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, configured for XNX toxic and oxygen sensors |
|
XNX-UTAE-NHNNN |
XNX Transmitter, HART® over 4-20mA output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, configured for XNX toxic and oxygen sensors |
|
XNX-UTAE-RNNNN |
XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, configured for XNX toxic and oxygen sensors |
|
XNX-UTAE-RHNNN |
XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, configured for XNX toxic and oxygen sensors |
|
XNX-UTAE-MNNNN |
XNX Transmitter, HART® over 4-20mA and Modbus output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, configured for XNX toxic and oxygen sensors |
|
XNX-UTAE-MHNNN |
XNX Transmitter, HART® over 4-20mA and Modbus output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, configured for XNX toxic and oxygen sensors |
|
XNX-UTAE-FNNNN |
XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, configured for XNX toxic and oxygen sensors |
|
XNX-UTAE-FHNNN |
XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, configured for XNX toxic and oxygen sensors |
|
|
|
|
XNX Stainless Steel Transmitter UL/CSA for use with XNX Toxic and Oxygen Sensors |
||
|
|
|
XNX-UTSE-NNNNN |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, configured for XNX toxic and oxygen sensors. |
|
XNX-UTSE-NHNNN |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with local HART® interface port, configured for XNX toxic and oxygen sensors. |
|
XNX-UTSE-RNNNN |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs, configured for XNX toxic and oxygen sensors. |
|
XNX-UTSE-RHNNN |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, configured for XNX toxic and oxygen sensors. |
|
XNX-UTSE-MNNNN |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output, configured for XNX toxic and oxygen sensors. |
|
XNX-UTSE-MHNNN |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, configured for XNX toxic and oxygen sensors. |
|
XNX-UTSE-FNNNN |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, configured for XNX toxic and oxygen sensors. |
|
XNX-UTSE-FHNNN |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, configured for XNX toxic and oxygen sensors. |
|
3.2. XNX TOXIC AND OXYGEN CARTRIDGES With SENSORS |
A range of toxic and oxygen sensors for use with the XNX transmitter. Sensors have replaceable cartridges.
XNXXSO1SS |
XNX sensor Oxygen 0-25%VOL |
XNXXSC1SS |
XNX sensor Carbon Monoxide 0-300ppm (100 to 999ppm, 100ppm) |
XNXXSH3SS |
XNX sensor Hydrogen Sulfide 0-15ppm |
XNXXSH1SS |
XNX sensor Hydrogen Sulfide 0-15ppm (10 to 50ppm, 1ppm) |
XNXXSH2SS |
XNX sensor Hydrogen Sulfide 0-100ppm (50 to 500ppm, 10ppm) |
XNXXSL1SS |
XNX sensor Chlorine 0-5.0ppm (5.0 to 20.0ppm, 5.0ppm) |
XNXXSL2SS |
XNX sensor Chlorine Low Range, 0-5.00ppm |
XNXXSS1SS |
XNX sensor Sulfur Dioxide 0-15.0ppm (5.0 to 20.0ppm, 5.0ppm) |
XNXXSS2SS |
XNX sensor Sulfur Dioxide 0-50.0ppm (20.0 to 50.0ppm, 10.0ppm) |
XNXXSX1SS |
XNX sensor Chlorine Dioxide 0-1.00ppm |
XNXXSM1SS |
XNX sensor Nitrogen Monoxide 0-100ppm |
XNXXSN1SS |
XNX sensor Nitrogen Dioxide 0-10.0ppm (5.0 to 50.0ppm, 5.0ppm) |
XNXXSG1SS |
XNX sensor Hydrogen 0-1000ppm |
XNXXSG2SS |
XNX sensor Hydrogen 0-10,000ppm |
XNXXSA1SS |
XNX sensor Ammonia 0-200ppm (50 to 200ppm, 50ppm) |
XNXXSA2SS |
XNX sensor Ammonia 0-1000ppm (200 to 1000ppm, 50ppm) |
XNXXSR1SS |
XNX sensor Hydrogen Chloride 0-10ppm (10.0 to 20.0ppm, 1.0ppm) |
XNXXSF1SS |
XNX sensor Hydrogen Fluoride 0-12.0ppm |
XNXXSP1SS |
XNX sensor Phosphine 0-1.2ppm |
XNXXSY1SS |
XNX sensor Hydrogen Cyanide 0-30.0ppm (Fixed Scale) |
XNXXSU1SS |
XNX sensor Fluorine 4 ppm |
XNXXSE1SS |
XNX Cartridge, Ethylene Oxide (ETO), 25.0ppm (user-selectable from 20.0ppm to 50.0ppm) |
3.3. XNX REPLACEMENT TOXIC AND OXYGEN SENSOR Cell |
Replacement toxic and oxygen sensor cell for use in the XNX toxic and oxygen sensor.
XNXO1SS |
XNX Cartridge Oxygen 0-25%VOL |
XNXC1SS |
XNX Cartridge Carbon Monoxide 0-300ppm (100 to 500ppm, 100ppm) |
XNXH3SS |
XNX Cartridge Hydrogen Sulfide 0-5ppm (1.5 to 5ppm, 0.1ppm) |
XNXH1SS |
XNX Cartridge Hydrogen Sulfide 0-15ppm (10 to 50ppm, 1ppm) |
XNXH2SS |
XNX Cartridge Hydrogen Sulfide 0-100ppm (50 to 500ppm, 10ppm) |
XNXL1SS |
XNX Cartridge Chlorine 0-5.0ppm |
XNXS1SS |
XNX Cartridge Sulfur Dioxide 0-15.0ppm (5.0 to 20.0ppm, 5.0ppm) |
XNXX1SS |
XNX Cartridge Chlorine Dioxide 0-1.00ppm |
XNXM1SS |
XNX Cartridge Nitrogen Monoxide 0-100ppm |
XNXN1SS |
XNX Cartridge Nitrogen Dioxide 0-10.0ppm (5.0 to 50.0ppm, 5.0ppm) |
XNXG1SS |
XNX Cartridge Hydrogen 0-1000ppm |
XNXG2SS |
XNX Cartridge Hydrogen 0-10,000ppm |
XNXR1SS |
XNX Cartridge Hydrogen Chloride 0-10ppm (10.0 to 20.0ppm, 1.0ppm) |
XNXA1SS |
XNX Cartridge Ammonia 0-200ppm (50 to 200ppm, 50ppm) |
XNXA2SS |
XNX Cartridge Ammonia 0-1000ppm (200 to 1000ppm, 50ppm) |
XNXF1SS |
XNX Cartridge Hydrogen Fluoride 0-12.0ppm |
XNXP1SS |
XNX Cartridge Phosphine 0-1.2ppm |
XNXY1SS |
XNX Cartridge Hydrogen Cyanide 0-30.0ppm (Fixed Scale) |
XNXE1SS |
XNX Cartridge Fluorine 4ppm |
XNXE1SS |
XNX Cell Kit, Ethylene Oxide (ETO), 25.0ppm (user-selectable from 20.0ppm to 50.0ppm) |
4. XNX Universal Transmitter- for use with Optima Plus Or Searchline Excel Detectors
XNX Transmitter for use with Optima Plus and Searchline Excel IR detectors. Order Optima Plus and Searchline Excel detectors separately from the appropriate section in the price list. Note kit part numbers including standard XNX transmitter configurations have been created for Searchline Excel detectors (see appropriate section in price list).
4.1. INSTRUMENT |
XNX Aluminuim Transmitter ATEX/IEC for use with Optima Plus and Searchline Excel Detectors |
XNX-AMAI-NNNNN |
XNX Transmitter, HART® over 4-20mA output, ATEX/IECEx, 5 x M25 entries, painted Aluminium, configured for Optima Plus and Excel |
XNX-AMAI-NHNNN |
XNX Transmitter, HART® over 4-20mA output and local HART® interface port, ATEX/IECEx, 4 x M25 entries, painted Aluminium, configured for Optima Plus and Excel |
XNX-AMAI-RNNNN |
XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays, ATEX/IECEx, 5 x M25 entries, painted Aluminium, configured for Optima Plus and Excel |
XNX-AMAI-RHNNN |
XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays and local HART® interface port, ATEX/IECEx, 4 x M25 entries, painted Aluminium, configured for Optima Plus and Excel |
XNX-AMAI-MNNNN |
XNX Transmitter, HART® over 4-20mA and Modbus output, ATEX/IECEx, 5 x M25 entries, painted Aluminium, configured for Optima Plus and Excel |
XNX-AMAI-MHNNN |
XNX Transmitter, HART® over 4-20mA and Modbus output and local HART® interface port, ATEX/IECEx, 4 x M25 entries, painted Aluminium, configured for Optima Plus and Excel |
XNX-AMAI-FNNNN |
XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output, ATEX/IECEx, 5 x M25 entries, painted Aluminium, configured for Optima Plus and Excel |
XNX-AMAI-FHNNN |
XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, ATEX/IECEx, 4 x M25 entries, painted Aluminium, configured for Optima Plus and Excel |
XNX Stainless Steel Transmitter ATEX/IEC for use with Optima Plus and Searchline Excel Detectors |
XNX-AMSI-NNNNN |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, configured for Optima Plus and Searchline Excel. |
XNX-AMSI-NHNNN |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with local HART® interface port, configured for Optima Plus and Searchline Excel. |
XNX-AMSI-RNNNN |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs, configured for Optima Plus and Searchline Excel. |
XNX-AMSI-RHNNN |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, configured for Optima Plus and Searchline Excel. |
XNX-AMSI-MNNNN |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output, configured for Optima Plus and Searchline Excel. |
XNX-AMSI-MHNNN |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, configured for Optima Plus and Searchline Excel. |
XNX-AMSI-FNNNN |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, configured for Optima Plus and Searchline Excel. |
XNX-AMSI-FHNNN |
XNX transmitter, HART® over 4-20mA output, ATEX/IEC approved, 5 x M25 entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, configured for Optima Plus and Searchline Excel. |
XNX Aluminuim Transmitter UL/CSA for use with Optima Plus and Searchline Excel Detectors |
XNX-UTAI-NNNNN |
XNX Transmitter, HART® over 4-20mA output, UL/CSA, 5 x 3/4"NPT entries, painted Aluminium, configured for Optima Plus and Excel |
XNX-UTAI-NHNNN |
XNX Transmitter, HART® over 4-20mA output and local HART® interface port, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, configured for Optima Plus and Excel |
XNX-UTAI-RNNNN |
XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA, 5 x 3/4"NPT entries, painted Aluminium, configured for Optima Plus and Excel |
XNX-UTAI-RHNNN |
XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays and local HART® interface port, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, configured for Optima Plus and Excel |
XNX-UTAI-MNNNN |
XNX Transmitter, HART® over 4-20mA and Modbus output, UL/CSA, 5 x 3/4"NPT entries, painted Aluminium, configured for Optima Plus and Excel |
XNX-UTAI-MHNNN |
XNX Transmitter, HART® over 4-20mA and Modbus output and local HART® interface port, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, configured for Optima Plus and Excel |
XNX-UTAI-FNNNN |
XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA, 5 x 3/4"NPT entries, painted Aluminium, configured for Optima Plus and Excel |
XNX-UTAI-FHNNN |
XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, configured for Optima Plus and Excel |
XNX Stainless Steel Transmitter UL/CSA for use with Optima Plus and Searchline Excel Detectors |
XNX-UTSI-NNNNN |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, configured for Optima Plus and Searchline Excel. |
XNX-UTSI-NHNNN |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with local HART® interface port, configured for Optima Plus and Searchline Excel. |
XNX-UTSI-RNNNN |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs, configured for Optima Plus and Searchline Excel. |
XNX-UTSI-RHNNN |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, configured for Optima Plus and Searchline Excel. |
XNX-UTSI-MNNNN |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output, configured for Optima Plus and Searchline Excel. |
XNX-UTSI-MHNNN |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, configured for Optima Plus and Searchline Excel. |
XNX-UTSI-FNNNN |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, configured for Optima Plus and Searchline Excel. |
XNX-UTSI-FHNNN |
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, configured for Optima Plus and Searchline Excel. |
5. Searchline Excel kits with XNX Transmitters |
Searchline Excel kits including standard XNX transmitter configured with HART® over 4-20mA output and local HART® port. For Searchline Excel kits including other XNX transmitter configurations contact Honeywell Analytics. |
5.1. INSTRUMENT |
Searchline Excel kits including standard XNX transmitter with HART® over 4-20mA outputs.
Searchline Excel Short Range 5m – 40m (15ft - 130ft) |
02104-N-XSAA |
Short range system 5m to 40m ATEX/IECEx complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates and brackets, Aluminium XNX with local HART® interface port and JB. |
02104-N-XSSA |
Short range system 5m to 40m ATEX/IECEx complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates and brackets, Stainless Steel XNX with local HART® interface port JB |
|
|
02104-N-XSAU |
Short range system 5m to 40m UL complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Aluminium XNX and junction box. |
02104-N-XSSU |
Short range system 5m to 40m UL complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Stainless Steel XNX and junction box. |
02104-N-XSAC |
Short range system 5m to 40m CSA complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Aluminium XNX and junction box. |
02104-N-XSSC |
Short range system 5m to 40m CSA complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Stainless Steel XNX and junction box. |
02104-N-NSNA |
Short range system 5m to 40m ATEX/IECEx complete TXR and RXR system, SS316 mounting plates and fitting for XNX. Add XNX and Junction box as required |
Searchline Excel Medium Range 20m – 120m |
02104-N-XMAA |
Medium range system 20m to 120m ATEX/IECEx complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates and brackets, Aluminium XNX with local HART® interface port and JB |
02104-N-XMSA |
Medium range system 20m to 120m ATEX/IECEx complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates and brackets, Stainless Steel XNX with local HART® interface port and JB |
|
|
02104-N-XMAU |
Medium range system 20m to 120m UL complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Aluminium XNX and junction box. |
02104-N-XMSU |
Medium range system 20m to 120m UL complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Stainless Steel XNX and junction box. |
02104-N-XMAC |
Medium range system 40m to 120m CSA complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Aluminium XNX and junction box. |
02104-N-XMSC |
Medium range system 40m to 120m CSA complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Stainless Steel XNX and junction box. |
02104-N-NMNA |
Excel line-of-sight gas detection system (without XNX, please order required XNX separately), medium range (40 to 120m), 4 to 20mA output, ATEX/IECEx, fully wired with flexible conduit, electro polished 316SS. Includes Tx, Rx, 316SS mounting plates, brackets and hardware. XNX and junciton boxes to be ordered seperately. |
Searchline Excel Long Range 20m – 200m |
02104-N-XLAA |
Long range system 20m to 200m ATEX/IECEx complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates and brackets, Aluminium XNX with local HART® interface port and JB |
02104-N-XLSA |
Long range system 20m to 200m ATEX/IECEx complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates and brackets, Stainless Steel XNX with local HART® interface port JB |
|
|
02104-N-XLAU |
Long range system 20m to 200m UL complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Aluminium XNX and junction box. |
02104-N-XLSU |
Long range system 20m to 200m UL complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Stainless Steel XNX and junction box. |
02104-N-XLAC |
Long range system 120m to 200m CSA complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Aluminium XNX and junction box. |
02104-N-XLSC |
Long range system 120m to 200m CSA complete TXR and RXR system, fully wired with flexible conduit, SS316 mounting plates, brackets, Stainless Steel XNX and junction box. |
02104-N-NLNA |
Excel line-of-sight gas detection system (without XNX, please order required XNX separately), long range (120 to 200m), 4 to 20mA output, ATEX/IECEx, fully wired with flexible conduit, electro polished 316SS. Includes Tx, Rx, 316SS mounting plates, brackets and hardware. XNX and junciton boxes to be ordered seperately. |
5.2. XNX and Searchline Excel Alignment Kits |
02104-N-4006X |
Short Range Excel & XNX alignment and conformity kit including telescope, carry case and test filters (no SHC1) |
02104-N-4007X |
Long/Medium Range Excel & XNX alignment and conformity kit including telescope, carry case and test filters (no SHC1) |
6. XNX Universal Transmitter Accessories and Spare Parts |
6.1. XNX ACCESSORIES & SPARES |
1226A0358 |
Pipe Mount Kit |
1226A0355 |
Ceiling Mount Bracket Kit |
S3KDMK |
Duct mounting kit for Series 3000 and XNX EC toxic sensors |
1226A0382 |
MPD Interface Adaptor (for use with S3KDMK Duct Mount Kit) |
1226A0411 |
Calibration Gas Flow Adaptor (for use with MPD) |
S3KCAL |
Calibration cup (flow adapter) for Series 3000 and XNX EC toxic sensors |
S3KRMK |
Remote mounting kit for Series 3000 and XNX EC toxic sensors |
02000-A-1645 |
Flow Housing Assembly (for Sensepoint, Signalpoint, Satellite (with adapter), XNX MPD and Series 2000) |
00780-A-0035 |
Flow Housing (full stainless steel, for high temp applications) |
S3KWP |
Weatherproof housing with bump test port for use with Series 3000 and XNX EC toxic sensors |
SPXCDWP |
Standard Weather Protection, uses for ECC toxic sensor cartridges in outdoor |
02000-A-1640 |
Weatherproof cap for use with combustible detector including remote gassing nozzle (for Sensepoint, Signalpoint, Satellite (with adapter), XNX MPD and Series 2000) |
02000-A-1635 |
Weatherproof cap for use with toxic detector including remote gassing nozzle (for Sensepoint, Signalpoint, Satellite (with adapter), XNX MPD and Series 2000) |
02000-A-1642 |
Collecting cone for use with flammable detector (for Sensepoint, Signalpoint, Satellite (with adapter), XNX MPD and Series 2000) |
SPXCDCC |
Collecting cone for use with lighter than air gases |
2441-0022 |
UL/CSA Aluminium Junction Box Assembly (for remote mount of MPD sensors) |
00780-A-0100 |
Honeywell Junction Box- Bartec OTB122 With Continuity Plate 1 X 25mm - 3 X 20mm Entries - ATEX Approved |
|
|
MCT404-XA-02-00 |
Honeywell HART Communicator for use with XNX Range and Optima Plus gas detectors, Intrinsically-safe, with FM Class I, Div 1/Zone 1, ATEX and IECEx Zone 1 approvals. Including rechargeable battery, mains powered charger and docking station |
50079567-011 |
Leather carrying case for MCT404 (Stylus & shoulder strap included) |
|
|
10000-A-0004 |
SS316 Mounting Plate for 2" to 2.5" pipe mounting (Sourced from HAAP Singapore) |
10000-A-0054 |
XNX Transmitter Sunshade (Sourced from HAAP Singapore) |
10000-A-0190 |
2” Pipe mount “V” bracket, M10, including washers & nuts, SS316 (Sourced from HAAP Singapore) |
XNX-FLOW |
SS316 Flow Housing for ECC Sensors - for Aspirated Sampling Systems (Sourced from HAAP Singapore) |
|
|
1226A0354 |
Remote Gassing Kit |
1226-0257 |
M25 Stopping Plug w/ protective cap and O-ring |
1226-0258 |
3/4" NPT Stopping Plug w/ protective cap and O-ring |
|
|
0235-0238 |
Replacement O-ring for XNX front cover |
1226A0302 |
Terminal Block Assembly 6-Pin for XNX EC |
1226A0304 |
Terminal Block Assembly 9-Pin for XNX mV |
1226A0305 |
IR Terminal Block Assembly Kit includes: 9-Pin & |
1226A0306 |
Relay Terminal Block Assembly Kit includes: 9-Pin and 2-Pin blocks |
1226A0307 |
Terminal Block Assembly 10-Pin for XNX Modbus |
|
|
1226-9001 |
XNX Transmitter Spare Pod, Infrared Personality, No Options |
1226-9002 |
XNX Transmitter Spare Pod, Infrared Personality, Relay Option |
1226-9003 |
XNX Transmitter Spare Pod, Infrared Personality, ModBus Options |
1226-9004 |
XNX Transmitter Spare Pod, Infrared Personality, Foundation Fieldbus Options |
1226-9009 |
XNX Transmitter Spare Pod, Millivolt Personality, No Options |
1226-9010 |
XNX Transmitter Spare Pod, Millivolt Personality, Relay Option |
1226-9011 |
XNX Transmitter Spare Pod, Millivolt Personality, ModBus Option |
1226-9012 |
XNX Transmitter Spare Pod, Millivolt Personality, Foundation Fieldbus Options |
1226-9005 |
XNX Transmitter Spare Pod, Electrochemical Personality, No Options |
1226-9006 |
XNX Transmitter Spare Pod, Electrochemical Personality, Relay Option |
1226-9007 |
XNX Transmitter Spare Pod, Electrochemical Personality, ModBus Option |
1226-9008 |
XNX Transmitter Spare Pod, Electrochemical Personality, Foundation Fieldbus Options |
|
|
XNX-RLY |
Relay Option |
XNX-MB |
ModBus Option |
XNX-FFB |
Foundation Fieldbus Option |
|
|
SPXNXSERVK |
XNX Service Kit, Including Replacement O-ring for XNX front cover, I.S. modules screws (2 pieces), Earth screw and bracket (3 pieces), O-ring for MPD housing, MPD Sinter O-ring, MPD Sinter locking screw (set screw), ECC sensor - 3 off O-rings, ECC Sensor Lid O-ring, ECC sensor lid - locking screw (set screw) |
SPXNXTOOLK |
XNS Tool Kit, Including Magnetic Wand/Screwdriver, Small Screwdriver (for use with Relay board and IR personality board), HEX L-KEY 2.0MM, HEX-L-KEY 1.5MM X 3.06"L |