XNX UNIVERSAL TRANSMITTER
XNX is an extremely flexible gas transmitter that can be configured to accept an input from any of the Honeywell Analytics range of gas sensor technologies. It can also be configured to provide all the industry standard output signals; a key feature of the XNX transmitter is that it comes with HART over 4-20mA as standard. This enables users to have a single type of interface to all their gas detection needs, even when different types of detectors are employed.
XNX is ATEX, IECEx, UL, CSA and SIL2 approved and is housed in a flameproof enclosure available in either marine grade painted aluminium LM25 or stainless steel 316. A large backlit multilingual LCD clearly indicates the unit’s status using a combination of text, digits and icons. Users can configure or conduct routine maintenance via magnet switches without ever needing to open the unit. An optional local IS HART® terminal port is also available if local interrogation is required. Local LEDs are also provided to indicate the unit’s status at a glance.
Honeywell气体探测器XNX通用变送器与Sensepoint标准或705 HT型可燃传感器一起使用
XNX Universal Transmitter excluding Sensepoint High Temp or 705 HT Sensor or Sensepoint standard Flammable LEL/ PPM
or remote configurations of MPD. Order required sensor separately from other appropriate section of price list.
XNX铝变送器UL/CSA,用于705高温和感测点FL传感器
XNX-UTAV-NNNNN
XNX Transmitter, HART® over 4-20mA output, UL/CSA, 5 x 3/4"NPT entries, painted Aluminium, configured for 705 High Temperature and Sensepoint FL Sensor
XNX-UTAV-NHNNN
XNX Transmitter, HART® over 4-20mA output and local HART® interface port, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, configured for 705 High Temperature and Sensepoint FL Sensor
XNX-UTAV-RNNNN
XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA, 5 x 3/4"NPT entries, painted Aluminium, configured for 705 High Temperature and Sensepoint FL Sensor
XNX-UTAV-RHNNN
XNX Transmitter, HART® over 4-20mA output and 3 fault/alarm relays and local HART® interface port, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, configured for 705 High Temperature and Sensepoint FL Sensor
XNX-UTAV-MNNNN
XNX Transmitter, HART® over 4-20mA and Modbus output, UL/CSA, 5 x 3/4"NPT entries, painted Aluminium, configured for 705 High Temperature and Sensepoint FL Sensor
XNX-UTAV-MHNNN
XNX Transmitter, HART® over 4-20mA and Modbus output and local HART® interface port, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, configured for 705 High Temperature and Sensepoint FL Sensor
XNX-UTAV-FNNNN
XNX Transmitter, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA, 5 x 3/4"NPT entries, painted Aluminium, configured for 705 High Temperature and Sensepoint FL Sensor
XNX-UTAV-FHNNN
XNX Transmit
ter, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, UL/CSA, 4 x 3/4"NPT entries, painted LM25, configured for 705 High Temperature and Sensepoint FL Sensor
XNX不锈钢发射机UL/CSA与705型高温传感器和感测点FL传感器配套使用
XNX-UTSV-NNNNN
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, configured for mV sensors.
XNX-UTSV-NHNNN
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 4 x 3/4"NPT entries, painted 316 stainless steel, with local HART® interface port, configured for mV sensors.
XNX-UTSV-RNNNN
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs, configured for mV sensors.
XNX-UTSV-RHNNN
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 4 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, configured for mV sensors.
XNX-UTSV-MNNNN
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output, configured for mV sensors.
XNX-UTSV-MHNNN
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 4 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, configured for mV sensors.
XNX-UTSV-FNNNN
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 5 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, configured for mV sensors.
XNX-UTSV-FHNNN