中文 | ENGLISH
热线电话:021-37825236
当前位置:首页 > 产品中心 > Honeywell霍尼韦尔 > XNX通用型
Honeywell霍尼韦尔XNX发射机UL/CSA与MPD红外丙烷传感器 XNX-UTAV-NHIF1
Honeywell霍尼韦尔XNX发射机UL/CSA与MPD红外丙烷传感器 XNX-UTAV-NHIF1

产品分类:XNX通用型

产品型号:

产品品牌:

产品备注:

详情说明

XNX UNIVERSAL TRANSMITTER

XNX is an extremely flexible gas transmitter that can be configured to accept an input from any of the Honeywell Analytics range of gas sensor technologies. It can also be configured to provide all the industry standard output signals; a key feature of the XNX transmitter is that it comes with HART over 4-20mA as standard. This enables users to have a single type of interface to all their gas detection needs, even when different types of detectors are employed.


XNX is ATEX, IECEx, UL, CSA and SIL2 approved and is housed in a flameproof enclosure available in either marine grade painted aluminium LM25 or stainless steel 316. A large backlit multilingual LCD clearly indicates the unit’s status using a combination of text, digits and icons. Users can configure or conduct routine maintenance via magnet switches without ever needing to open the unit. An optional local IS HART® terminal port is also available if local interrogation is required. Local LEDs are also provided to indicate the unit’s status at a glance.


XNX Aluminium Transmitter UL/CSA with MPD Infrared Hydrocarbon (Propane) Sensor 0-100%LEL

XNX-UTAV-NNIF1
XNX Gas Detector, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-UTAV-NHIF1
XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-UTAV-RNIF1
XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-UTAV-RHIF1
XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-UTAV-MNIF1
XNX Gas Detector, HART® over 4-20mA and Modbus output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-UTAV-MHIF1
XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-UTAV-FNIF1
XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX-UTAV-FHIF1
XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD IR hydrocarbon (Propane) sensor 0-100%LEL

XNX Stainless Steel Transmitter UL/CSA with MPD Infrared Hydrocarbon (Propane) Sensor 0-100%LEL


XNX-UTSV-NNIF1
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 4 x 3/4"NPT entries, painted 316 stainless steel, including MPD IR flammable sensor 0-100%LEL.

XNX-UTSV-NHIF1
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 3 x 3/4"NPT entries, painted 316 stainless steel, with local HART® interface port, including MPD IR flammable sensor 0-100%LEL.

XNX-UTSV-RNIF1
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 4 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs, including MPD IR flammable sensor 0-100%LEL.

XNX-UTSV-RHIF1
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 3 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, including MPD IR flammable sensor 0-100%LEL.

XNX-UTSV-MNIF1
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 4 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output, including MPD IR flammable sensor 0-100%LEL.

XNX-UTSV-MHIF1
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 3 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, including MPD IR flammable sensor 0-100%LEL.

XNX-UTSV-FNIF1
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 4 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, including MPD IR flammable sensor 0-100%LEL.

XNX -UTSV-FHIF1
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 3 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, including MPD IR flammable sensor 0-100%LEL.