中文 | ENGLISH
热线电话:021-37825236
当前位置:首页 > 产品中心 > Honeywell霍尼韦尔 > XNX通用型
Honeywell霍尼韦尔催化式气体传感器 不锈钢XNX Universal XNX-UTSV-MNCB1
Honeywell霍尼韦尔催化式气体传感器 不锈钢XNX Universal XNX-UTSV-MNCB1

产品分类:XNX通用型

产品型号:

产品品牌:

产品备注:

详情说明

XNX UNIVERSAL TRANSMITTER

XNX is an extremely flexible gas transmitter that can be configured to accept an input from any of the Honeywell Analytics range of gas sensor technologies. It can also be configured to provide all the industry standard output signals; a key feature of the XNX transmitter is that it comes with HART over 4-20mA as standard. This enables users to have a single type of interface to all their gas detection needs, even when different types of detectors are employed.


XNX is ATEX, IECEx, UL, CSA and SIL2 approved and is housed in a flameproof enclosure available in either marine grade painted aluminium LM25 or stainless steel 316. A large backlit multilingual LCD clearly indicates the unit’s status using a combination of text, digits and icons. Users can configure or conduct routine maintenance via magnet switches without ever needing to open the unit. An optional local IS HART® terminal port is also available if local interrogation is required. Local LEDs are also provided to indicate the unit’s status at a glance.


XNX Aluminium Transmitter UL/CSA with MPD Catalytic Sensor 0-100%LEL

XNX-UTAV-NNCB1
XNX Gas Detector, HART® over 4-20mA output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

XNX-UTAV-NHCB1
XNX Gas Detector, HART® over 4-20mA output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

XNX-UTAV-RNCB1
XNX Gas Detector, HART® over 4-20mA output and 3 fault/alarm relays, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

XNX-UTAV-RHCB1
XNX Gas Detector, HART® over 4-20mA output, 3 fault/alarm relays and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

XNX-UTAV-MNCB1
XNX Gas Detector, HART® over 4-20mA and Modbus output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

XNX-UTAV-MHCB1
XNX Gas Detector, HART® over 4-20mA and Modbus output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

XNX-UTAV-FNCB1
XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output, UL/CSA, 4 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL

XNX-UTAV-FHCB1
XNX Gas Detector, HART® over 4-20mA and Foundation Fieldbus™ output and local HART® interface port, UL/CSA, 3 x 3/4"NPT entries, painted Aluminium, includes MPD catalytic sensor 0-100%LEL


XNX Stainless Steel Transmitter UL/CSA with MPD Catalytic Sensor 0-100%LEL

XNX-UTSV-NNCB1
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 4 x 3/4"NPT entries, painted 316 stainless steel, including MPD catalytic sensor 0-100%LEL.

XNX-UTSV-NHCB1
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 3 x 3/4"NPT entries, painted 316 stainless steel, with local HART® interface port, including MPD catalytic sensor 0-100%LEL.

XNX-UTSV-RNCB1
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 4 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs, including MPD catalytic sensor 0-100%LEL.

XNX-UTSV-RHCB1
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 3 x 3/4"NPT entries, painted 316 stainless steel, with alarm and fault relay outputs and local HART® interface port, including MPD catalytic sensor 0-100%LEL.

XNX-UTSV-MNCB1
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 4 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output, including MPD catalytic sensor 0-100%LEL.

XNX-UTSV-MHCB1
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 3 x 3/4"NPT entries, painted 316 stainless steel, with Modbus® output and local HART® interface port, including MPD catalytic sensor 0-100%LEL.

XNX-UTSV-FNCB1
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 4 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output, including MPD catalytic sensor 0-100%LEL.

XNX-UTSV-FHCB1
XNX transmitter, HART® over 4-20mA output, UL/CSA approved, 3 x 3/4"NPT entries, painted 316 stainless steel, with optional Foundation Fieldbus™ output and local HART® interface port, including MPD catalytic sensor 0-100%LEL.



点击量:
请先加QQ再询价
服务热线
微信公众账号

二维码